MAXTERRA® All Products Brochure.
The complete product line, including specifications, certifications, applications, and system-level performance data.
View Brochure →
MAXTERRA® MgO Cement Panels support multifamily projects with non-combustible exterior wall sheathing, abuse resistant interior wall boards, and structural, fire-rated, and sound-deadening floor assemblies that eliminate wet-laid gypsum. ICC-ES evaluated, UL fire-rated, and proven in the field.
These guides help your team evaluate MAXTERRA® products and floor systems for multifamily projects.
The complete product line, including specifications, certifications, applications, and system-level performance data.
View Brochure →
Compare MAXTERRA® underlayment and single-layer structural floor systems for multifamily and hotel projects.
Download Guide →
Explore dry-installed floor systems as an alternative to wet-laid gypsum.
Download Guide →
For builders using or considering CFS framing, with code-ready wall and floor documentation.
Download Guide →Multifamily developers and GCs are caught between IBC Type III code requirements and a wet-trade floor system that fights your schedule at every turn.
5–7 day (or more) cure cycle per floor. Wet-laid gypsum locks in waiting time at every level, compressing your ability to sequence trades efficiently.
Moisture damage and callbacks. Wet-laid gypsum introduces bulk water during construction, a leading cause of mold, delaminated flooring, and post-occupancy warranty claims.
Subcontractor mobilization risk. Wet-laid gypsum requires a specialty sub. Scheduling conflicts, material shortages, or quality disputes can halt your entire project.
MOC chemistry. Some MgO boards use magnesium oxychloride (MOC) formulas, which may corrode fasteners and framing members and fail industry standards.
FRTW compliance ambiguity. Fire-retardant-treated wood is a combustible material treated after the fact, not inherently noncombustible, despite common field assumptions.
Our MOS (magnesium oxysulfate) chemistry delivers what your project schedule, code inspector, and ownership group all need from a single product system.
Dry Installation. No water introduced to the building envelope, ever. Full floor system installs with standard fasteners in one trade sequence.
Inherently Non-combustible. ASTM E136 classified, not a treated combustible material. Qualifies for Type III exterior wall applications as referenced by the IBC.
ICC-ES evaluated. ESR-5193 (sheathing), ESR-5192 (underlayment), ESR-5194 (structural floor panel), ESR-5506 (MagRock® Premium Wall board). Documentation ready for plan review and field inspection.
MOS chemistry. MAXTERRA uses magnesium oxysulfate chemistry and is designed for moisture resistance, dimensional stability, and reduced chloride-related corrosion risk compared to chloride-based MgO products.
UL H531, 2-hour rated. Full assembly rating achieved with fewer layers than competing products. Simplifies procurement and inspection while saving money.
3/4" MAXTERRA® Structural Floor Panel replaces both OSB subfloor and wet-laid gypsum in a single layer. Maximum schedule compression, zero wet trade, zero separate topping layer.
Thickness 3/4" - span rating 24" OC
Load capacity 133 psf at L/600 deflection
ASTM E136 Non-Combustible MOS chemistry
ICC-ES ESR-5194
UL H531 2-Hour Rated
1/2" MAXTERRA® underlayment installs over existing OSB subfloor, set by your framing sub in the same pass. Eliminates wet-laid gypsum subcontractor, 5-7 day (or more) cure time, moisture risk, and flooring adhesion failures in one product swap.
Thickness 1/2" - installs over existing OSB
No cure time - dry install, no wet trade
ICC-ES ESR-5192
Replaces OSB or plywood sheathing and gypsum sheathing on exterior wall framing. Noncombustible per ASTM E136, qualifying for Type III exterior wall applications as referenced by the IBC. No FRTW substitution arguments. Available in 1/2" and 5/8" for CFS and wood-frame applications.
Thickness 1/2" & 5/8" - CFS & wood framing
ASTM E136 Noncombustible - MOS chemistry
ICC-ES ESR-5193
Interior wall panel replacing standard gypsum panel products. ASTM E84 Class A rated. ASTM G21 mold resistance - 0 growth observed. MOS chemistry, designed for moisture resistance and reduced chloride-related corrosion risk.
Thickness 3/8", 1/2", 5/8"
ASTM E84 Flame Spread 0, Smoke 5 - Class A
ICC-ES ESR-5506 replaces interior gypsum
When you need a 2-hour fire-rated floor assembly... more layers, heavier steel,
and specialty material requirements add up to more cost.
| Assembly Feature |
MAXTERRA®H531 | UL DesignH515 | UL DesignG575 | UL DesignH509 | UL DesignH514 |
|---|---|---|---|---|---|
| Ceiling Gypsum | 1 layer, ULIX or Type C | 1–2 layers, Type ULIX | 2 layers, Type C | 2 layers, Type C | 1 layer, Type C (National Gypsum only) |
| Additional Floor Topping | None | Varies by assembly | None | Varies* | None |
| Sound Mat in Assembly | None | Specified in some | None | None | None |
| Truss Steel Gauge | 20 ga | 18 ga | 16 ga | 16 ga | 16 ga |
| Insulation | Any qualifying batt | Any qualifying batt | Any qualifying batt | Any qualifying batt | R-13, 0.92 density (restricted) |
| Blocking Required | None (tongue & groove) | None | Required* | Specified in some | None |
Data sourced from UL assembly listings H531, H515, G575, H509, H514.
*Underlayment note: UL Design No. H509 does not require a floor topping. The listed subfloor panel's product certification (IAPMO UES ER-0808) does not permit its use without a separate underlayment, so a panel underlayment or poured topping is required.
*Blocking Note - UL Design No. G575 was tested with no panel-edge blocking. The listed subfloor panel uses a shiplap edge profile. Where structural panels do not have approved tongue-and-groove joints, Table 2304.8(3) of the 2024 International Building Code requires panel edges to be supported with blocking unless an approved exception applies. Final edge-support requirements should be verified by the project design professional and authority having jurisdiction.
MAXTERRA® has been specified and installed on
Multifamily Projects across the country.
Class A Garden-Style Multifamily
MAXTERRA® Single Layer Structural Floor Panels
Wood-Framed Construction
Cleburne, Texas
266
Multifamily Residential
MAXTERRA® Single Layer Structural Floor Panels
Cold-Formed Steel (CFS) Framing
Plant City, Florida
96
Multifamily
1/2” MAXTERRA® Flooring Underlayment
Wood-Framed Construction
Dover, Delaware
Underlayment over OSB Subfloor
The most highly certified MgO product on the market. Every claim backed
by ICC-ES evaluation reports and UL assembly listings, not marketing claims.
Covers MAXTERRA® MgO sheathing for exterior wall applications on CFS and wood-frame construction. Noncombustible per ASTM E136, qualifying for Type III exterior wall applications as referenced by the IBC. This is the report that ends the FRTW conversation before it starts.
Covers MAXTERRA® 1/2" underlayment installed over OSB subfloor as a wet-laid gypsum replacement. Addresses fire performance, structural contribution, and moisture resistance. Provides the documentation path for permit submission on floor-ceiling assemblies.
Covers MAXTERRA® 3/4" single-layer structural floor panel as a combined replacement for OSB subfloor and wet-laid gypsum. Span rating, load tables, and deflection criteria included, everything your structural engineer needs for the floor framing plan. .
Full UL-listed 2-hour fire-rated assembly for CFS truss construction with MAXTERRA® floor panel and single layer of ceiling gypsum. Fewer components than competing H-series assemblies, simpler procurement, simpler inspection, same rating.
Covers MagRock® MgO wall board for interior wall applications as a replacement for traditional gypsum panels. ASTM E84 Flame Spread Index of 0, Smoke Developed Index of 5. Zero mold growth per ASTM G21. The documentation path for interior fire-resistant wall assemblies without gypsum.
The only MgO panel with a verified Environmental Product Declaration (EPD) for the North American market. Contributes to LEED v4 credit pathways including MR Credit: Building Product Disclosure and Environmental Product Declarations. VOC-free, quartz silica-free, and manufactured through a low-carbon mineral-based process.
UL-listed 1-hour fire-rated floor-ceiling assembly for wood open truss construction. Refer to the listing for the specified materials and installation requirements.
Noncombustible, not just fire-rated. MAXTERRA® MgO panels are classified as noncombustible per ASTM E136 testing, qualifying for Type III exterior wall applications as referenced by the IBC. Fire-retardant-treated wood (FRTW) is a combustible material treated to reduce flame spread, it is not classified as noncombustible. MAXTERRA®’s ICC-ES ESR-5193 report is the documentation building officials need to confirm compliance without case-by-case interpretation.
Learn how to mitigate the 9 most common multifamily construction risks →
Yes, with one of two paths depending on where you are in the framing sequence. If OSB subfloor is already installed, MAXTERRA® 1/2" underlayment (ESR-5192) goes over it and eliminates the wet-laid gypsum pour. If you’re at pre-subfloor stage, the 3/4" structural floor panel (ESR-5194) replaces both OSB and wet-laid gypsum in a single layer. In both cases, your framing subcontractor can install the panels, no new sub required. Contact your NEXGEN local rep for a project-specific installation sequence.
MAXTERRA® uses magnesium oxysulfate (MOS) chemistry. Many commodity MgO panels use magnesium oxychloride (MOC). MOC panels absorb atmospheric moisture over time, leach chloride salts, and corrode embedded fasteners and metal framing. This can lead to structural degradation that doesn’t manifest until post-occupancy. MAXTERRA uses magnesium oxysulfate chemistry and is designed for moisture resistance, dimensional stability, and reduced chloride-related corrosion risk compared to chloride-based MgO products. MAXTERRA® holds the most extensive portfolio of third-party testing and certifications of any MgO product on the market, including four ICC-ES evaluation reports and a UL-listed 2-hour fire-rated assembly.
When compared on an installed-cost basis, the MAXTERRA® underlayment path (OSB subfloor + 1/2" MAXTERRA® underlayment) typically costs less per square foot than the traditional assembly (OSB subfloor + wet-laid gypsum underlayment + sound mat). MAXTERRA® eliminates pour scheduling, cure time, and moisture-related callbacks, which further reduces total project cost. Contact your NEXGEN local rep for a project-specific cost comparison.
Read why one builder replaced wet-laid gypsum with MAXTERRA® →
MAXTERRA® is the only MgO product with ICC-ES certification for both cold-formed steel (CFS) and wood-frame construction. The structural wall sheathing (ESR-5193) is evaluated for CFS and wood framing. The structural floor panel (ESR-5194) is evaluated for both CFS and wood joist systems. The fire-and-water-resistant underlayment (ESR-5192) is evaluated for CFS truss systems, which is the dominant framing system in Type III multifamily. If your project uses a hybrid framing system or non-standard truss layout, contact your NEXGEN representative. The ICC-ES reports include span tables and load data that your structural engineer can reference for project-specific conditions.
Learn about MAXTERRA®’s dual CFS and wood-frame certification →
From exterior sheathing to floor systems to interior wall board, get the documentation and support your project needs.